Background
Indo Gulf Fertilizer is a leading manufacturer of ammonia, urea, di-methyl-formamide, ammonium bicarbonate etc.

Process Overview
The ammonia and urea production units generate their hydrogen (H2), di-nitrogen (N2) and carbon dioxide (CO2) feeds through a common reformer.

Outlet gases from the reformer are passed through the absorber, where H2 along with other light gases are separated, while the CO2 is removed through absorption in the solution. H2 and other light gases along with slipped CO2 from the top of the absorber are passed to the methanation section. The methanator converts the residual CO2 to methane to increase the catalyst life of the ammonia reactor.

The rich solution from the absorber is then stripped in the regenerator and the CO2 gas is used to produce urea. The lean solution from the regenerator bottom is sent back to the absorber.

Customer Requirements
In the existing condition, the CO2 slippage from the absorber was very high (~1200 ppm). This led to an increase in the load on methanator and also simultaneously increasing the volume of purge stream from NH3 loop.

The customer wanted to revamp the system in order to:
- Reduce slippage of CO2
- Increase plant capacity without sacrificing absorber efficiency

Problem analysis
During the study of the existing system it was noted that Pall Rings were used as mass transfer media in the packed towers. The Pall Rings inherently have a drawback of higher pressure drop and performance limitations for mass transfer. This was resulting in increased load on the compressor, finally leading to slippage of excess CO2.

Solutions Provided
Hydraulic rating of existing towers along with the tower internals was done using Medal-Pak® and following results were noted:
- The pressure drop was found to be appreciably lower than that of Pall Rings
- The capacity could be increased by 20%
- Minor modification of the existing internals to handle higher loads was also suggested

Further, based on the process overview it was predicted that the slippage of CO2 would be in the range from ~ 1200 ppm.

Accordingly, Medal-Pak® tower packings were manufactured, supplied and installed. During the shutdown the internals were modified on site.

Results achieved
- After the packing replacement, CO2 slip decreased to 500 ppm at higher capacity of 105%
- Steam consumption in re-generator decreased to 10%

The customer, Indo Gulf Fertilizer, was satisfied with the results claiming that:

“Munters has supplied us the equipment under technical evaluation by Haldor Topsoe A/s, Denmark for our Ammonia Revamp Project. Munters was involved in the design and engineering of the internals and subsequent supervision of installation of them. They have done the job successfully to our entire satisfaction and the equipment is working satisfactorily.”.

Hurtige fakta

  • Customer: Fertilizer industry
  • Location: Western India
  • Tower Name: CO2 Absorber and Regenerator
  • Tower Diameter: 4900 mm; 2730-3940 mm
  • Mass Transfer Equipment: Tower Packing and Internals
  • Products used: Random packing, Medal-Pak®, Collector Trays, Internals

Hvordan kan vi hjælpe dig?

Tilbage til startsiden
Ved at vælge godkender du vores cookie policies

Ikke valid bruger identifikation

Ups! Der er noget gik galt. Prøv igen senere

Ikke valid bruger identifikation

Ups! Der er noget gik galt. Prøv igen senere