The MCD100 combines traditional Munters strengths like efficiency and robustness with modern state of the art technology like modulating RH control and communication.
Low energy consumption and reliability are important in todays processes. Our modern control system together with high efficient fans which, meet the EU Ecodesign directive, supported with frequency converters give you numerous options to optimise your energy consumption. The Energy Recovery Purge (ERP) is available as a standard option in order to save energy.
The MCD100 is equipped with a number of alarm functions to ensure total control of the dehumidification process. Frame casing and outer panels are made of corrosion resistant AluZink and coated in RAL 7035.
The MCD100 dehumidifier covers a wide range of needs by providing a variety of standard functions. The numerous options will allow pre- and post treatment by simply adding mechanical and electrical components.
The MCD100 can be supplied with 3 different reactivation alternatives - electrical, steam and gas. A service indicator activates when a preventative service is due, this is a standard feature. To make installation easier the process fan inlet has been designed to allow for different outlet positions.
The electrical equipment conforms to EN 60204 (IEC204). The MCD series of dehumidifiers conform to both harmonised European standards and technical specifications for CE marking.
Доступно в China, Korea, Australia, India, Thailand, Singapore, Europe, Middle East, Africa
информация о продукте
Техническая спецификация
Опции
Сравнение
Загрузки
10000 m3/h | |
300 Pa | |
11 kW | |
300 Pa | |
3060 m3/h | |
2.2 kW | |
30 | |
103.9 kW | |
43.1 g | |
42.2 g | |
115.9 kW/h | |
13.9 kW/h | |
380V 3-50 Hz Electrical | 183 A |
380V 3-50 Hz Steam/Gas | 27 A |
400V 3-50Hz Electrical | 173 A |
400V 3-50Hz Steam/Gas | 26 A |
440V 3-60Hz Electrical | 158 A |
415V 3-50Hz Steam/Gas | 25 A |
415V 3-50Hz Electrical | 167 A |
440V 3-60Hz Steam/Gas | 24 A |
7 bar(g) | |
47.8 g/s | |
48.9 g/s | |
10.04 m3/h | |
1910 kWh/kg | |
18-30 mbar | |
F | |
-20/+40 °C | |
33 IP | |
54 IP | |
91 dB(A) | |
G4 | |
WxDxH | 2891x1590x2575 mm |
1132 kg | |
337x630 mm | |
231x450 mm |
10000 m3/h | |
300 Pa | |
11 kW | |
300 Pa | |
3060 m3/h | |
2.2 kW | |
30 | |
103.9 kW | |
43.1 g | |
42.2 g | |
115.9 kW/h | |
13.9 kW/h | |
380V 3-50 Hz Electrical | 183 A |
380V 3-50 Hz Steam/Gas | 27 A |
400V 3-50Hz Electrical | 173 A |
400V 3-50Hz Steam/Gas | 26 A |
440V 3-60Hz Electrical | 158 A |
415V 3-50Hz Steam/Gas | 25 A |
415V 3-50Hz Electrical | 167 A |
440V 3-60Hz Steam/Gas | 24 A |
7 bar(g) | |
47.8 g/s | |
48.9 g/s | |
10.04 m3/h | |
1910 kWh/kg | |
18-30 mbar | |
F | |
-20/+40 °C | |
33 IP | |
54 IP | |
91 dB(A) | |
G4 | |
WxDxH | 2891x1590x2575 mm |
1132 kg | |
337x630 mm | |
231x450 mm |